Severity: Notice
Message: Trying to access array offset on value of type null
Filename: controllers/Website.php
Line Number: 123
Backtrace:
File: /home/mednizco/public_html/centrifuges.com/application/controllers/Website.php
Line: 123
Function: _error_handler
File: /home/mednizco/public_html/centrifuges.com/application/controllers/Website.php
Line: 36
Function: productdetail
File: /home/mednizco/public_html/centrifuges.com/index.php
Line: 321
Function: require_once
Severity: Notice
Message: Trying to access array offset on value of type null
Filename: controllers/Website.php
Line Number: 136
Backtrace:
File: /home/mednizco/public_html/centrifuges.com/application/controllers/Website.php
Line: 136
Function: _error_handler
File: /home/mednizco/public_html/centrifuges.com/application/controllers/Website.php
Line: 36
Function: productdetail
File: /home/mednizco/public_html/centrifuges.com/index.php
Line: 321
Function: require_once
Severity: Notice
Message: Trying to access array offset on value of type null
Filename: controllers/Website.php
Line Number: 137
Backtrace:
File: /home/mednizco/public_html/centrifuges.com/application/controllers/Website.php
Line: 137
Function: _error_handler
File: /home/mednizco/public_html/centrifuges.com/application/controllers/Website.php
Line: 36
Function: productdetail
File: /home/mednizco/public_html/centrifuges.com/index.php
Line: 321
Function: require_once
Atomic Absorption Spectrophotometer TRAS-601is an integrated computer data processing device whose wavelength ranges from 190 to 900nm. Spectrum bandwidth with ranges of 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm. Special devices for quick gas conversion and safety protection can be used to analyze air-acetylene and nitrogen oxide flames, extending the analytic elements to over 60. In addition, it has an LCD. It is a long-life and corrosion-resistant atomization system. The device is stable and dependable. To achieve a stable flame and low noise, the gas path system is outfitted with highly precise pressure and existing stabilizing devices.
Specifications
| Wavelength Range | 190 to 900 nm |
| Wavelength Accuracy | £ ±0.5 nm |
| Wavelength Repeatability | £ 0.3 nm (single direction) |
| Spectrum Bandwidth | 0.2 nm, 0.4 nm, 0.7nm, 1.4 nm, 2.4 nm, 5.0 nm |
| Resolution | <40% |
| Baseline stability | ±0.004 Abs/30 min |
| Characteristic concentration of copper | £ 0.04 mg/ml/1% |
| Detection limit of copper | £0.008 mg/ml |
| Background calibration ability | Greater than 30 times |
| RS232 | including |
| Printer | optional |
| Power supply | 220V 3A, 50 Hz |
| Package Dimensions | 1220×770×730 mm (Main instrument) 800×400×900 mm ( Accessories ) |
| Weight | 160 Kg |